Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
2.
Rev. iberoam. micol ; 35(2): 83-87, abr.-jun. 2018. tab
Artigo em Inglês | IBECS | ID: ibc-179563

RESUMO

Background: An increased incidence of fungal infections caused by Candida species, especially Candida glabrata and Candida krusei, which are less susceptible to azoles, has been observed. Standardized susceptibility testing is essential for clinical management and for monitoring the epidemiology of resistance. Aims: We evaluated the performance of two different susceptibility testing commercial methods, Vitek 2(R) and Sensititre YeastOne(R), and compared them with the standard broth microdilution method (CLSI). Methods: A total of 80 isolates of several Candida species (Candida albicans, Candida parapsilosis complex, Candida tropicalis, C. glabrata and C. krusei) were selected for this study. Results: We analyzed the categorical agreement (CA) between the methods, stratifying the disagreements. The average CA between the methods was 96.3% for Vitek 2(R) and 84% for Sensititre YeastOne(R). No very major errors were observed. Major errors and minor errors were found for all the isolates tested. With the azoles, both Vitek 2(R) and Sensititre YeastOne(R) had good and similar performance levels, except for C. tropicalis and C. krusei (Sensititre YeastOne(R) showed low CA, 56.2%). With the echinocandins, both methods showed good performance for C. albicans, C. parapsilosis and C. tropicalis. However, we observed important discrepancies for C. krusei with caspofungin: Vitek 2(R) had 100% CA while Sensititre YeastOne(R) had only 25%. With amphotericin B, both Vitek 2(R) and Sensititre YeastOne(R) had good performance with high CA. Conclusions: Despite the limited isolates tested, we concluded that both methods have good performance and are reliable for antifungal susceptibility testing. However, caspofungin activity against C. krusei and C. glabrata should be interpreted carefully when using Sensititre YeastOne(R) because we observed a low CA


Antecedentes: La incidencia de infecciones fúngicas provocadas por especies de Candida, especialmente por Candida glabrata y Candida krusei, menos sensibles a los azoles, ha ido en aumento. Los métodos estandarizados de estudio de la sensibilidad a los antifúngicos son fundamentales para el manejo clínico y para un mejor seguimiento de la epidemiología de la resistencia. Objetivos: Se evaluó la actividad de dos métodos comerciales diferentes para el estudio de la sensibilidad in vitro a los antifúngicos, Vitek 2(R) y Sensititre YeastOne(R), y se compararon con la técnica estándar de microdilución en caldo del CLSI. Métodos: Para este estudio se seleccionó un total de 80 cepas aisladas de varias especies de Candida (Candida albicans, Candida parapsilosis, Candida tropicalis, C. glabrata y C. krusei). Resultados: Se analizó la concordancia categórica (CC) entre los métodos y se estratificaron los desacuerdos. La CC media entre los métodos fue del 96,3% para Vitek 2(R) y del 84% para Sensititre YeastOne(R). No se observaron errores muy altos. Se encontraron errores mayores y menores en todos los aislamientos probados. Con los azoles, tanto Vitek 2(R) como YeastOne(R) presentaron rendimientos buenos y similares, excepto para C. tropicalis y C. krusei (Sensititre YeastOne(R) mostró baja CC, el 56,2%). Con las equinocandinas, los dos métodos mostraron buen rendimiento para C. albicans, C. parapsilosis y C. tropicalis. Sin embargo, se observaron discrepancias importantes para C. krusei con la caspofungina: Vitek 2(R) presentó el 100% de CC, mientras que Sensititre YeastOne(R) solo el 25%. Para la anfotericina B, Vitek 2(R) y Sensititre YeastOne(R) presentaron un buen rendimiento con una CC alta. Conclusiones: Aunque el número de cepas aisladas probadas fue limitado, concluimos que los dos métodos tienen un buen rendimiento y son fiables para la prueba de sensibilidad antifúngica. Sin embargo, la actividad de la caspofungina frente a C. krusei y C. glabrata mediante el método Sensititre YeastOne(R) debe interpretarse cuidadosamente, ya que se observa un valor bajo de CC


Assuntos
Humanos , Testes de Sensibilidade Microbiana/métodos , Candida/patogenicidade , Candidíase/tratamento farmacológico , Antifúngicos/farmacocinética , Sensibilidade e Especificidade , Candida glabrata/patogenicidade , Farmacorresistência Fúngica , Colorimetria/métodos
3.
Rev Iberoam Micol ; 35(2): 83-87, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29580699

RESUMO

BACKGROUND: An increased incidence of fungal infections caused by Candida species, especially Candida glabrata and Candida krusei, which are less susceptible to azoles, has been observed. Standardized susceptibility testing is essential for clinical management and for monitoring the epidemiology of resistance. AIMS: We evaluated the performance of two different susceptibility testing commercial methods, Vitek 2® and Sensititre YeastOne®, and compared them with the standard broth microdilution method (CLSI). METHODS: A total of 80 isolates of several Candida species (Candida albicans, Candida parapsilosis complex, Candida tropicalis, C. glabrata and C. krusei) were selected for this study. RESULTS: We analyzed the categorical agreement (CA) between the methods, stratifying the disagreements. The average CA between the methods was 96.3% for Vitek 2® and 84% for Sensititre YeastOne®. No very major errors were observed. Major errors and minor errors were found for all the isolates tested. With the azoles, both Vitek 2® and Sensititre YeastOne® had good and similar performance levels, except for C. tropicalis and C. krusei (Sensititre YeastOne® showed low CA, 56.2%). With the echinocandins, both methods showed good performance for C. albicans, C. parapsilosis and C. tropicalis. However, we observed important discrepancies for C. krusei with caspofungin: Vitek 2® had 100% CA while Sensititre YeastOne® had only 25%. With amphotericin B, both Vitek 2® and Sensititre YeastOne® had good performance with high CA. CONCLUSIONS: Despite the limited isolates tested, we concluded that both methods have good performance and are reliable for antifungal susceptibility testing. However, caspofungin activity against C. krusei and C. glabrata should be interpreted carefully when using Sensititre YeastOne® because we observed a low CA.


Assuntos
Antifúngicos/farmacologia , Candida/efeitos dos fármacos , Candidíase/microbiologia , Testes de Sensibilidade Microbiana/métodos , Candida/isolamento & purificação , Colorimetria , Humanos , Testes de Sensibilidade Microbiana/instrumentação , Reprodutibilidade dos Testes , Especificidade da Espécie
4.
Einstein (Sao Paulo) ; 15(1): 34-39, 2017.
Artigo em Inglês, Português | MEDLINE | ID: mdl-28444086

RESUMO

OBJECTIVE: To investigate whether the urine dipstick screening test can be used to predict urine culture results. METHODS: A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. RESULTS: The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). CONCLUSION: A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. OBJETIVO: Verificar se a triagem de urina por fitas reativas é capaz de predizer a cultura de urina. Métodos Estudo retrospectivo realizado entre janeiro e dezembro de 2014 com 8.587 pacientes, com solicitação médica de triagem de urina (fita), sedimento urinário e cultura de urina. FORAM ANALISADOS: sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e curva ROC. RESULTADOS: Foram positivas 17,5% das culturas. O nitrito apresentou sensibilidade de 28% e especificidade de 99%. O valor preditivo positivo foi de 89% e o valor preditivo negativo de 87%. Esterase apresentou sensibilidade de 79% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram de 51% e 95%, respectivamente. A combinação de nitrito ou esterase positivos apresentou sensibilidade de 85% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram, respectivamente, 53% e 96%. O sedimento positivo (mais de dez leucócitos por microlitro) apresentou sensibilidade de 92% e especificidade de 71%. O valor preditivo positivo foi 40% e o negativo, 98%. A combinação de nitrito e sedimento urinário positivos apresentou sensibilidade de 82% e especificidade de 99%. Os valores preditivos positivo e negativo foram 91% e 98%, respectivamente. Para o nitrito ou esterase positivos mais os leucócitos positivos, a sensibilidade foi de 94% e a especificidade de 84%. O valor preditivo positivo foi de 58% e o negativo foi de 99%. Com base na curva ROC, o melhor indicador de urocultura positiva foi a associação entre a esterase ou nitrito positivos na fita mais os leucócitos positivos no sedimento, seguido por nitrito e esterase positivos, sedimento urinário positivo isolado, esterase positiva isolada, nitrito positivo isolado e, finalmente, pela associação entre nitrito e sedimento urinário positivos (AUC: 0,845, 0,844, 0,817, 0,814, 0,635 e 0,626, respectivamente). CONCLUSÃO: Uma urocultura negativa pode ser prevista com resultados negativos na fita. Portanto, este teste pode ser um preditor confiável de urocultura negativa.


Assuntos
Bacteriúria/urina , Urinálise/instrumentação , Urinálise/métodos , Adulto , Análise de Variância , Pré-Escolar , Contagem de Colônia Microbiana , Esterases/urina , Humanos , Leucócitos , Masculino , Pessoa de Meia-Idade , Nitritos/urina , Padrões de Referência , Valores de Referência , Estudos Retrospectivos , Sensibilidade e Especificidade , Infecções Urinárias/urina , Urina/microbiologia
5.
Einstein (Säo Paulo) ; 15(1): 34-39, Jan.-Mar. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-840287

RESUMO

ABSTRACT Objective To investigate whether the urine dipstick screening test can be used to predict urine culture results. Methods A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. Results The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). Conclusion A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture.


RESUMO Objetivo Verificar se a triagem de urina por fitas reativas é capaz de predizer a cultura de urina. Métodos Estudo retrospectivo realizado entre janeiro e dezembro de 2014 com 8.587 pacientes, com solicitação médica de triagem de urina (fita), sedimento urinário e cultura de urina. Foram analisados sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e curva ROC. Resultados Foram positivas 17,5% das culturas. O nitrito apresentou sensibilidade de 28% e especificidade de 99%. O valor preditivo positivo foi de 89% e o valor preditivo negativo de 87%. Esterase apresentou sensibilidade de 79% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram de 51% e 95%, respectivamente. A combinação de nitrito ou esterase positivos apresentou sensibilidade de 85% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram, respectivamente, 53% e 96%. O sedimento positivo (mais de dez leucócitos por microlitro) apresentou sensibilidade de 92% e especificidade de 71%. O valor preditivo positivo foi 40% e o negativo, 98%. A combinação de nitrito e sedimento urinário positivos apresentou sensibilidade de 82% e especificidade de 99%. Os valores preditivos positivo e negativo foram 91% e 98%, respectivamente. Para o nitrito ou esterase positivos mais os leucócitos positivos, a sensibilidade foi de 94% e a especificidade de 84%. O valor preditivo positivo foi de 58% e o negativo foi de 99%. Com base na curva ROC, o melhor indicador de urocultura positiva foi a associação entre a esterase ou nitrito positivos na fita mais os leucócitos positivos no sedimento, seguido por nitrito e esterase positivos, sedimento urinário positivo isolado, esterase positiva isolada, nitrito positivo isolado e, finalmente, pela associação entre nitrito e sedimento urinário positivos (AUC: 0,845, 0,844, 0,817, 0,814, 0,635 e 0,626, respectivamente). Conclusão Uma urocultura negativa pode ser prevista com resultados negativos na fita. Portanto, este teste pode ser um preditor confiável de urocultura negativa.


Assuntos
Humanos , Masculino , Pré-Escolar , Adulto , Pessoa de Meia-Idade , Bacteriúria/urina , Urinálise/instrumentação , Urinálise/métodos , Padrões de Referência , Valores de Referência , Infecções Urinárias/urina , Urina/microbiologia , Contagem de Colônia Microbiana , Estudos Retrospectivos , Análise de Variância , Sensibilidade e Especificidade , Esterases/urina , Leucócitos , Nitritos/urina
6.
Einstein (Säo Paulo) ; 10(4): 439-441, Oct.-Dec. 2012.
Artigo em Inglês | LILACS | ID: lil-662468

RESUMO

OBJECTIVE: To evaluate ertapenem disk performance to predict Klebsiella pneumonie carbapenemase production by Gram-negative bacilli. METHODS: All Gram-negative bacilli isolated between January 2010 and June 2011 were tested by disk diffusion (OxoidTM) for sensitivity to ertapenem, meropenem and imipenem. Resistant or intermediate sensitivity strains (diameter <22 mm for ertapenem) were also tested for the blaKPC gene by polymerase chain reaction. Disk predictive positive value for Klebsiella pneumoniae carbapenemase and specificity were calculated. RESULTS: Out of the 21839 cultures performed, 3010 (13.78%) were positive, and Gram-negative bacilli were isolated in 708 (23.52%) of them. Zone of inhibition diameter for ertapenem disk was <22 mm for 111 isolates, representing 15.7% of all Gram-negative isolates. The PCR assay for blaKPC detected 40 Klebsiella pneumoniae carbapenemase-producing strains. No strains intermediate or resistant to meropenem and imipenem were sensitive to ertapenem. The ertapenem disk presented a positive predictive value of 36% to predict blaKPC and 89% specificity. CONCLUSION: The resistance of Gram-negative bacilli detected by disk diffusion against ertapenem does not predict Klebsiella pneumoniae carbapenemase production. Other mechanisms, such as production of other betalactamases and porin loss, may be implicated. The need to confirm the presence of the blaKPC is suggested. Therefore, ertapenem was a weak predictor for discriminating strains that produce Klebsiella pneumoniae carbapenemase.


OBJETIVO: Avaliar o desempenho do disco de ertapenem para predizer micro-organismos produtores de Klebsiella pneumoniae carbapenemase. MÉTODOS: Bacilos Gram-negativos isolados em cultura entre janeiro de 2010 e junho de 2011 foram testados por disco-difusão (OxoidTM) para ertapenem, meropenem e imipenem. As cepas consideradas intermediárias ou resistentes (halo<22mm) para ertapenem foram encaminhadas para a pesquisa do blaKPC por reação em cadeia da polimerase. Calcularam-se o valor preditivo positivo e a especificidade do disco. RESULTADOS: Foram realizadas 21.839 culturas nesse período, sendo 3.010 (13,78%) positivas. Bacilos Gram-negativos foram isolados em 708 (23,52%) destas. A zona de inibição do disco de ertapenem foi <22mm para 111 (15,67%) dos isolados. A pesquisa do blaKPC caracterizou 40 cepas produtoras de Klebsiella peneumoniae carbapenemase. Não houve nenhum caso de disco intermediário ou resistente para meropenem ou imipenem com ertapenem sensível. O valor preditivo positivo foi de 36% e a especificidade calculada do disco de ertapenem para produção de Klebsiella pneumoniae carbapenemase foi de 89% em nosso serviço. CONCLUSÃO: A resistência ao disco de ertapenem não define bacilo produtor de Klebsiella pneumoniae carbapenemase. Mecanismos, como produção de outras betalactamases e perda de porinas, podem estar implicados. Sugerese a necessidade da confirmação da presença do gene blaKPC. O ertapenem, portanto, mostrou-se fraco preditor para discriminar cepas produtoras de Klebsiella pneumoniae carbapenemase.


Assuntos
Humanos , Antibacterianos/farmacologia , Proteínas de Bactérias/biossíntese , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão/métodos , Klebsiella pneumoniae/enzimologia , beta-Lactamases/biossíntese , beta-Lactamas/farmacologia , Resistência beta-Lactâmica , Brasil , Proteínas de Bactérias/análise , Bactérias Gram-Negativas/isolamento & purificação , Klebsiella pneumoniae/efeitos dos fármacos , Testes de Sensibilidade Microbiana , Reação em Cadeia da Polimerase , Valor Preditivo dos Testes , beta-Lactamases/análise
7.
Einstein (Sao Paulo) ; 10(4): 439-41, 2012.
Artigo em Inglês, Português | MEDLINE | ID: mdl-23386083

RESUMO

OBJECTIVE: To evaluate ertapenem disk performance to predict Klebsiella pneumonie carbapenemase production by Gram-negative bacilli. METHODS: All Gram-negative bacilli isolated between January 2010 and June 2011 were tested by disk diffusion (Oxoid™) for sensitivity to ertapenem, meropenem and imipenem. Resistant or intermediate sensitivity strains (diameter < 22 mm for ertapenem) were also tested for the blaKPC gene by polymerase chain reaction. Disk predictive positive value for Klebsiella pneumoniae carbapenemase and specificity were calculated. RESULTS: Out of the 21839 cultures performed, 3010 (13.78%) were positive, and Gram-negative bacilli were isolated in 708 (23.52%) of them. Zone of inhibition diameter for ertapenem disk was < 22 mm for 111 isolates, representing 15.7% of all Gram-negative isolates. The PCR assay for blaKPC detected 40 Klebsiella pneumoniae carbapenemase-producing strains. No strains intermediate or resistant to meropenem and imipenem were sensitive to ertapenem. The ertapenem disk presented a positive predictive value of 36% to predict blaKPC and 89% specificity. CONCLUSION: The resistance of Gram-negative bacilli detected by disk diffusion against ertapenem does not predict Klebsiella pneumoniae carbapenemase production. Other mechanisms, such as production of other betalactamases and porin loss, may be implicated. The need to confirm the presence of the blaKPC is suggested. Therefore, ertapenem was a weak predictor for discriminating strains that produce Klebsiella pneumoniae carbapenemase.


Assuntos
Antibacterianos/farmacologia , Proteínas de Bactérias/biossíntese , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão/métodos , Klebsiella pneumoniae/enzimologia , beta-Lactamases/biossíntese , beta-Lactamas/farmacologia , Proteínas de Bactérias/análise , Brasil , Ertapenem , Bactérias Gram-Negativas/isolamento & purificação , Humanos , Klebsiella pneumoniae/efeitos dos fármacos , Testes de Sensibilidade Microbiana , Reação em Cadeia da Polimerase , Valor Preditivo dos Testes , Resistência beta-Lactâmica , beta-Lactamases/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...